Product details
SARS-CoV-2/RSV+Influenza A/B Antigen Test Kit (LFIA) is an immunochromatography based one step in vitro test. It is designed for the rapid qualitative determination of SARS-CoV-2 Virus nucleocapsid antigen,RSV Antigen ,Influenza A nucleocapsid antigen and Influenza B virus nucleocapsid antigen in anterior nasal swabs from individuals suspected of COVID-19, RSV,suspected of SARS-CoV-2、RSV 、Influenza A and Influenza B within the first four days of symptom onset. The test kit is designed for use as self-testing. This test kit is intended use for individuals by 18 or older with clinical symptoms of SARS-CoV-2、RSV、Influenza A and Influenza B infection or who are Influenza A and Influenza B.SARS-CoV-2/RSV & Influenza A/B Antigen Combo Rapid Test Kit (LFIA) shall not be used as sole basis to diagnose or exclude SARS-CoV-2, RSV,Influenza A and Influenza B infection.
ARTG ID: 427686
Easy to read three panel/four test immunoassay testing kit
Tests for COVID-19 (SARS-CoV-2), Respiratory syncytial virus (RSV), Influenza A and Influenza B
Fast results
Only 3 drops needed for each panel
Easy to follow instructions
DESCRIPTION
Detect and differentiate between COVID-19, RSV, Influenza A, and Influenza B with the Cellife Antigen Test Kit. This professional-grade test kit is easy to use and provides results within minutes, making it a valuable tool for timely and accurate diagnosis.
SARS-CoV-2/RSV+Influenza A/B Antigen Test Kit (LFIA) is an immunochromatography based one step in vitro test. It is designed for the rapid qualitative determination of SARS-CoV-2 Virus nucleocapsid antigen,RSV Antigen ,Influenza A nucleocapsid antigen and Influenza B virus nucleocapsid antigen in anterior nasal swabs from individuals suspected of COVID-19, RSV,suspected of SARS-CoV-2、RSV 、Influenza A and Influenza B within the first four days of symptom onset. The test kit is designed for use as self-testing. This test kit is intended use for individuals by 18 or older with clinical symptoms of SARS-CoV-2、RSV、Influenza A and Influenza B infection or who are Influenza A and Influenza B.SARS-CoV-2/RSV & Influenza A/B Antigen Combo Rapid Test Kit (LFIA) shall not be used as sole basis to diagnose or exclude SARS-CoV-2, RSV,Influenza A and Influenza B infection.
Features
Easy to read three panel/four test immunoassay testing kit
Tests for COVID-19 (SARS-CoV-2), Respiratory syncytial virus (RSV), Influenza A and Influenza B
Fast results
Only 3 drops needed for each panel
Accuracy;
COVID-19: 97.55%
FLUA: 97.14%
FLUB: 96.26%
RSV: 96.66%
Available as a single test, box of 4 or box of 10
Use & Dosage
Each test can only be used once
Interpretation of any result after 20 minutes may result in wrong test results
Children aged 2 to 15 years old should have their samples collected and tested by an adult. Do not use the test for anyone under 2 years of age
A positive result cannot determine whether you are infectious
Positive results do not rule out bacterial infection or coinfection with other viruses.
If the result is positive,one must still confirm the results immediately by a laboratory PCR test.
False negative results are more likely to occur if the test is performed after 5 days of symptom onset
False negative results are more likely to occur in the later phase of infection and in asymptomatic individuals
A negative result does not rule out infection with another type of respiratory virus
Negative results does not preclude SARS-CoV-2 infection and the person not being infectious. If symptoms persist , please confirmed via a laboratory PCR-test.
Even if the result is negative, you still need to observed all protective and hygienic measures
The test cannot differentiate between SARS-CoV-1 and SARS-CoV-2 Virus
Repeat testing is recommend(between 24-48 hours after your first test)if there is an ongoing suspicion of infection,being in a high risk setting or where there is an occupational risk or other requirement
Warnings, Storage & Disposal
Do not use after the expiry date.
Read the Package insert carefully before use and use onlythe ingredients included in this test cassette
Make sure that the foil pouch containing the test cassette isnot damaged before opening it for use. The test cassette should be used within 30 minutes after opening the foil pouch.
Do not eat, drink or smoke in the area where the samples and kits are handled
Carry out the test at a room temperature of 15 - 30 °C.
Humidity and temperature can influence the results.
Shipping & delivery